In medical AI, the authority grants authorisation and other actors measure the benefit
Evidence for medical AI passes through the hands of authorities, technology assessors, developers, hospitals and evidence synthesisers, and each measures for its own decision. Most misreadings arise where one actor's figure is used for another actor's decision.
How this was made: this essay was written by the author's own research and analysis system from the cited sources; Zoltán Varga edited the topic, structure and final text. The cited works are the source of its factual claims.
In news about a medical AI system, the most often repeated fact is the authorisation, yet the regulatory decision is only one stage on the path of the evidence. By the time a model's output matters for a patient's case, a regulator has approved its marketing, a health technology assessment body has evaluated or not yet evaluated its added value, a hospital has integrated it into its workflow, and, in the best case, someone other than the developer has re-measured it. These actors ask different questions about the same system because they are responsible for different decisions.
The actors give institutional form to the two questions that have organised the previous parts of the series: where error enters the chain from research to patient, and for whose decision the evidence is prepared. Each stands at a point in the chain, and each makes the benchmark of a particular addressee mandatory.
The authority decides on placing on the market
The US Food and Drug Administration (FDA) maintains a public list of artificial intelligence-enabled medical devices authorised for marketing. According to the authority's website, devices on the list met premarket requirements, including an overall, focused review of safety and effectiveness. Devices were selected primarily based on AI-related terms appearing in the summaries of the authorisation documents; the list is updated periodically, and the authority itself notes that it is not comprehensive 1. The list is therefore an authorisation register. It testifies that a device has passed requirements relating to its intended use, but it says little about whether its use improves patient outcomes. From the list's description, it is not clear whether the higher levels of the five-level scale discussed in the second part, the demonstration of the effect of use, were part of the decision.
A learning system poses a particular problem for the authority because the model may change after it is placed on the market. According to the FDA's announcement of 3 December 2024, the authority published its final guidance at that time on what a predetermined change control plan should contain in the marketing submission for AI-based device software 2. As I read it, the authorisation thereby also covers a trajectory of change, and what is known about performance along that trajectory comes primarily from the manufacturer's data.
In the European Union, two legal acts intersect. According to the joint guidance issued in June 2025 by the Artificial Intelligence Board and the Medical Device Coordination Group, the medical device regulations address the risks of software but do not explicitly deal with the risks specific to AI systems; the AI Act supplements them. Medical AI is classified as high-risk if it is itself a medical device or a safety component of one, and if its conformity is assessed by a third party, a notified body designated under the medical device regulations; the classification is therefore determined by the device class under those regulations 3. Deirdre Ahern's 2025 preprint, Operationalising AI Regulatory Sandboxes under the EU AI Act, highlights the risk of regulatory sandboxes: if Member States set them up differently, the uniform interpretation of the Act is endangered, and developers may choose the environment more favourable to them. According to the author, participation is voluntary, a sandbox cannot relax legal requirements, and it does not confer a presumption of conformity 4.
On the pharmaceutical side, two scientific committees of the European Medicines Agency (EMA) adopted a reflection paper on AI used in the drug lifecycle in September 2024 5. According to the Agency's 2025 AI monitoring report, the AI Act entered the phase of practical application in February 2025 with prohibited uses and the AI literacy obligation 6, and on 14 January 2026 the EMA and the FDA jointly published ten principles on good AI practice, which cover the entire drug lifecycle from early research through clinical trials and manufacturing to safety monitoring, and according to the Agency's statement, future guidance will build on these 7.
The technology assessor asks about added value
After authorisation, the next question is whether it is worth it for the healthcare system. According to EU Regulation 2021/2282 on health technology assessment, joint EU clinical assessments of anticancer and advanced therapy medicinal products containing new active substances began on 12 January 2025, those of medicines for rare diseases will follow in 2028, and those of other medicines in 2030, while medical devices in the higher risk classes are selected by the Commission in implementing acts. The joint assessment is limited to the scientific analysis of relative effects and the certainty of those effects; it contains no value judgement on overall clinical added value; Member States decide on this and on economic issues 8.
This division of labour institutionalises one of the main theses of the second part. The estimation of relative effect can be common knowledge at the population level, while the decision on how much this effect is worth belongs to the funder and may vary by country. In the case of an AI-based device, this implies that regulatory authorisation and technology assessment answer different questions: one addresses whether the device functions as intended, the other how much better it is compared to existing care.
The benchmark at national level is exemplified by the framework of the English technology assessment body, NICE, which sets standards for evidence on digital health technologies. According to the institute's description, the framework sorts technologies into evidence tiers, is intended to help commissioners and evaluators who decide on procurement make more consistent decisions, and has covered AI and data-driven technologies with adaptive algorithms since August 2022. The same description also draws the line: meeting the standards constitutes neither the institute's evaluation or approval nor regulatory authorisation 9.
The World Health Organization (WHO) guidance issued in 2021, Ethics and governance of artificial intelligence for health, establishes six consensus principles as the result of eighteen months of expert work, and makes recommendations on how all actors in the public and private sectors can remain accountable to healthcare workers and affected communities 10. The WHO's role is norm-setting: the organisation does not grant authorisations, and its benchmark gains weight in healthcare systems that build their own regulations. Soft law holds a similar status within the Union. Nikos Th. Nikolinakos's book notes that the ethics guidelines on trustworthy AI drawn up by the high-level expert group set up by the Commission expresses the group's opinion, cannot be regarded as the Commission's official position, and aims to provide a unified ethical benchmark among Member States 11.
The evidence synthesiser reads the reported data
Cochrane describes itself as an independent, non-profit international network of healthcare researchers, professionals, patients and carers, which produces systematic reviews and, according to its own statement, does not accept funding that could influence its reviews 12. According to Michael Quinn Patton's methodological handbook, the profession recognises these reviews as the benchmark for high-quality information on the effectiveness of healthcare interventions, and within the network a dedicated working group deals with incorporating the results of qualitative research into effectiveness reviews 13. The synthesiser's role is thus twofold: it summarises and determines what evidence counts towards the summary.
The limitation of this role also lies in the sources. Ben Goldacre's book Bad Pharma describes how, in 2009, during an anticipated influenza pandemic, the British and Australian governments asked the Cochrane group dealing with respiratory diseases to update its previous reviews on an anti-influenza drug. The 2008 review still found evidence for a reduction in complications, but then a Japanese paediatrician pointed out on the Cochrane website, beneath the review, that the favourable conclusion was essentially determined by data from a single industry-funded meta-analysis. According to Goldacre, this comment marked a turning point in how people think about the functioning of evidence-based medicine 14. The thesis associated with the name of John Ioannidis in the first part here takes institutional form: the synthesis can only work with the quality of the data it receives, and if the source data are with the manufacturer, the synthesiser can at most point out the gap. The same situation applies to medical AI, because most of the performance data originate from the developer.
Developer measurement and independent verification
Developers' position is described most matter-of-factly by the 2026 preprint by Fazliddin Shermatov, Stephane Robin and Aldo Geuna, AI Innovation and Firm Performance in the Medical Device Industry. The authors start from the premise that an FDA authorisation leaves a dated trace that can be linked to a company, and by linking authorisation, patent, publication and financial data at company level, they found that external AI research collaboration goes hand in hand with bringing AI-based devices to market, more strongly for small companies. The effect was greatest for industry and clinical partners, smallest for university partners, while companies bringing AI devices to market showed higher labour productivity; the effect on profitability proved weaker and did not persist in all model variants 15. The preprint measures placing on the market as the outcome from the company's perspective, which is accurate for its own question, but because of how the question is framed it says nothing about patient benefit.
How far the developer's own measurement and independent verification can diverge is shown by Andrew Wong and colleagues' 2021 study, External Validation of a Widely Implemented Proprietary Sepsis Prediction Model in Hospitalized Patients. The authors examined the Epic Sepsis Model, a proprietary sepsis prediction model implemented, according to the study, in hundreds of US hospitals, within the Michigan Medicine healthcare system, across 38,455 hospital admissions of 27,697 patients. The model's discriminatory ability at the admission level yielded an area under the curve of 0.63, where 0.5 indicates random chance and 1 perfect ranking; the vendor's internal documentation reported values between 0.76 and 0.83. At the proposed alert threshold, the model flagged 18 per cent of admissions and missed 67 per cent of sepsis patients. The authors suggest the difference likely arises because they excluded predictions generated after the onset of sepsis; when a sensitivity analysis included values from the first three hours after onset, the metric improved to 0.80 16.
Some major technology companies offer open models, thereby shifting the burden of measurement. According to Google's health website, MedGemma is the company's most advanced open model for joint interpretation of medical text and images, optimised for developing healthcare applications, from analysing radiological images to summarising medical notes 17. This is the company's description of its own product; the website reports no independent clinical measurement, and with an open foundation model, clinical evidence may be generated by whoever builds a specific application from it.
Hospitals: implementation, announcements and their own measurement
The hospital is the actor that sees the system at work on its own patients, and so it alone can measure local performance. Thomas H. Davenport and Nitin Mittal judge in their book All-in On AI that in healthcare there is still no traditional organisation fundamentally reshaped by AI. Using the example of the Cleveland Clinic, they describe how AI applications appear in many places within the organisation, development is coordinated by a cross-organisational professional community relying on analytics, IT and ethics departments, and the benefit is mostly operational, enabling faster and more accurate decisions. At the time the book was written, the hospital was working on introducing an anaesthesiology pre-operative risk score, which rebuilt the earlier rule-based score on machine learning 18. The description concerns the implementation process; the passage does not provide data on impact measurement.
Announcements from health systems should be read in the same way. According to an announcement of 30 June 2025 by England's health ministry, an AI-based early warning system, still under development, is being built to flag patient safety problems from routine hospital data and staff reports, and a flag would lead the care quality regulator to launch an inspection 19. The statement records a plan and an intention to deploy, not evaluation results. The sepsis study at Michigan Medicine shows the other side of the hospital's role: there, the health system's researchers measured a model already in use on their own patients, and the result differed from the vendor's figure 16. The hospital is thus both a user and the most natural place for independent verification, but of these two roles, the first is the more common in the sources.
The research site builds the common benchmark
One characteristic tool of research sites is the public competition, in which teams compare their solutions on the same dataset. The 2023 preprint by Andriy Myronenko and colleagues describes their own solution submitted to the KiTS 2023 competition for the automatic segmentation of the kidney and kidney tumour on three-dimensional CT scans, which, according to the authors, secured first place with an average Dice score of 0.835, that is, a metric between 0 and 1 measuring the overlap between machine and expert segmentation 20. The competition leaderboard makes methods comparable, yet with the concepts used in the second part it remains at a lower level of validation: it measures how accurate the segmentation is on a fixed dataset, but not whether better segmentation changes patient care.
Another role of the research site is independent validation, for which the examination of the sepsis model serves as an example, and this role has no institutional channel like that of authorisation. According to the data of Shermatov and co-authors, moreover, university ties contributed least to bringing devices to market 15; thus, independent measurement and product development proceed on two separate tracks.
The path of evidence traverses institutional gaps
No one owns the evidence for medical AI along the whole of its path, and I consider this the most important observation on the map of actors. The authority measures performance against the intended use for placing on the market, while the technology assessor asks for the relative effect and leaves the value judgement to the Member State. The synthesiser can only organise the reported data, whereas the developer reports what it measured for its own decision. The hospital is the only one that sees its own patients, yet it is asked to measure less often than to implement.
Thus, the error locations of the first part become institutional gaps. Reporting bias arises between the developer and the synthesiser, the gap between the finding and the disease between the authority and the technology assessor, and the deterioration of local performance between the developer and the hospital, and no actor's remit fully covers any of them. The most serious misreading, as I see it, is when authorisation is cited as evidence of clinical benefit and the vendor's accuracy figure as an estimate of local performance, because in both cases a figure prepared for a different addressee is placed at the centre of the decision. The case of the sepsis model also shows that the gap can be closed by independent measurement, and the most natural place for this measurement is the health system.
From institutional benchmark to working method
The actors' rules, guidelines and announcements become reality in professional work: in the checklists for trial reports, in external validation, in the integration of decision support and in post-market surveillance. The series concludes with practices, with how the profession applies these benchmarks today. I consider the map of actors important because, for every number about medical AI, it shows which institution measured it, for which decision, and which actor was left out of the measurement.
Recommended reading
- Andrew Wong et al.: External Validation of a Widely Implemented Proprietary Sepsis Prediction Model in Hospitalized Patients (JAMA Internal Medicine, 181(8), 1065–1070). The study by Wong and colleagues is a model example of independent external validation: it shows how much a widely used model's performance measured in a hospital can differ from the data reported by the developer.
- AI Innovation and Firm Performance in the Medical Device Industry (Fazliddin Shermatov, Stephane Robin, Aldo Geuna). The preprint by Shermatov, Robin and Geuna measures AI innovation in medical device companies through the authorisation register, thereby making visible what the market counts as a result.
- Bad Pharma: How Medicine is Broken, and How We Can Fix it (Ben Goldacre). Goldacre's book is about the accessibility of drug research data and shows what an evidence synthesiser can and cannot know when the data are held by the manufacturer.
- Ethics and governance of artificial intelligence for health (World Health Organization). The WHO guidance is the international foundational text on ethical and governance principles for health AI.
- Operationalising AI Regulatory Sandboxes under the EU AI Act: The Triple Challenge of Capacity, Coordination and Attractiveness to Providers (Deirdre Ahern). Ahern's preprint analyses the risks of setting up regulatory sandboxes at EU level.
Sources
- [1] fda.gov: List of Artificial Intelligence-Enabled Medical Devices | FDA. fda.gov.
- [2] U.S. Food and Drug Administration (2024): FDA Roundup: December 3, 2024 (final guidance on predetermined change control plans for AI-enabled device software functions). U.S. Food and Drug Administration.
- [3] Artificial Intelligence Board, Medical Device Coordination Group (2025): AIB 2025-1 / MDCG 2025-6: Interplay between the MDR & IVDR and the Artificial Intelligence Act. Artificial Intelligence Board, Medical Device Coordination Group.
- [4] Deirdre Ahern (2025): Operationalising AI Regulatory Sandboxes under the EU AI Act: The Triple Challenge of Capacity, Coordination and Attractiveness to Providers. arXiv.
- [5] European Medicines Agency (2024): Artificial intelligence guidance (Reflection paper on the use of AI in the medicinal product lifecycle). European Medicines Agency.
- [6] ema.europa.eu: Forewords by Karl Broich, President of BfArM and NDSG co-chair, and Peter. ema.europa.eu.
- [7] European Medicines Agency (2026): EMA and FDA set common principles for AI in medicine development. European Medicines Agency.
- [8] European Parliament and Council (2021): Regulation (EU) 2021/2282 on health technology assessment. European Parliament and Council.
- [9] National Institute for Health and Care Excellence (NICE) (2022): Evidence standards framework (ESF) for digital health technologies. National Institute for Health and Care Excellence (NICE).
- [10] World Health Organization (2021): Ethics and governance of artificial intelligence for health. World Health Organization.
- [11] Nikos Th. Nikolinakos (2023): EU Policy and Legal Framework for Artificial Intelligence, Robotics and Related Technologies - The AI Act.
- [12] Cochrane (2026): About us. Cochrane.
- [13] Michael Quinn Patton (2014): Qualitative Research & Evaluation Methods: Integrating Theory and Practice (4th edition).
- [14] Ben Goldacre (2012): Bad Pharma: How Medicine is Broken, and How We Can Fix it.
- [15] Fazliddin Shermatov, Stephane Robin, Aldo Geuna (2026): AI Innovation and Firm Performance in the Medical Device Industry. arXiv.
- [16] JAMA Internal Medicine, 181(8), 1065–1070 (2021): Andrew Wong et al.: External Validation of a Widely Implemented Proprietary Sepsis Prediction Model in Hospitalized Patients. JAMA Internal Medicine, 181(8), 1065–1070.
- [17] health.google: Google for Health - Advancing Cutting-edge AI Capabilities. health.google.
- [18] Thomas H. Davenport, Nitin Mittal (2023): All-in On AI: How Smart Companies Win Big with Artificial Intelligence.
- [19] Department of Health and Social Care (2025): World-first AI system to warn of NHS patient safety concerns. Department of Health and Social Care.
- [20] Andriy Myronenko, Dong Yang, Yufan He, Daguang Xu (2023): Automated 3D Segmentation of Kidneys and Tumors in MICCAI KiTS 2023 Challenge. arXiv.